Safety Valves and Pressure Relief Valves

Every pressure system needs a last line of defence against overpressure. Valvenok supplies pressure relief valves, high-pressure safety valves, rupture discs and thermal relief devices from specialist partner manufacturers, from 50 psi instrument lines to 60,000 psi test systems, with certificates on request.

50 – 60,000 psi set pressureSS 316 instrument bodiesNPT, BSPT, BSPP and UNF
50 – 60,000psi

Set pressure range across the ranges

340configs

Instrumentation relief valves, online

5ranges

Relief valves, rupture discs and thermal relief

4brands

PANAM · Hiflux · Youngdo · Pietro Fiorentini

The basics

Safety Valve or Relief Valve?

A safety valve opens fully and almost instantly (it “pops”) when pressure reaches its set point. It is used on gases, steam and air, where pressure must be released fast. A relief valve opens gradually, in proportion to the overpressure, and suits liquids. A safety relief valve can do either, depending on the service.

Set pressurePressureLiftSafety valve: pops to full liftRelief valve:opens gradually
Lift against pressure (illustrative).

Our ranges

Our Safety and Relief Valve Ranges

Each range has its own page with full specifications and models. Pick the one that matches your pressure and service.

Instrumentation relief valves: RVL, RVH and PRVHPANAM

Instrumentation Relief Valves: RVL, RVH and PRVH

Compact SS 316 relief valves for instrument, sampling and hydraulic lines, spring-adjustable from 50 to 15,000 psi in 340 configurations.

  • RVL low pressure and RVH high pressure series, plus PRVH-10K and PRVH-15K for 10,000 and 15,000 psi
  • Sizes 1/4", 3/8", 1/2", M20×1.5 and 6, 8, 10 and 12 mm
  • NPT, BSPT and BSPP threads; female × female, male × female, male × OD and tube fitting ends
  • FKM seals; colour-coded spring ranges

For code-required protection on boilers and pressure vessels, use a certified safety valve.

High-pressure safety and relief valvesHiflux

High-pressure Safety and Relief Valves

Relief valves for test rigs, hydraulic systems, hydrogen and other high-pressure service, with UNF connections.

  • Proportional and field-adjustable relief valves for water and liquid service
  • Factory-set relief valves from 3,000 to 60,000 psi
  • KC-certified proportional gas relief valves, 1,000 to 29,000 psi
  • Certification varies by model
Rupture discs and safety headsHiflux

Rupture Discs and Safety Heads

Non-reclosing pressure relief. A rupture disc bursts at a set pressure; the safety head holds it in the line. Use it alone, or upstream of a relief valve to protect the valve from the process fluid.

  • Low, medium and high pressure discs, about 11,500 to 60,000 psi
  • Matching safety heads
  • UNF connections
~11,500 – 60,000 psiView rupture discs
Thermal relief for hydrogen cylinder valvesYoungdo

Thermal Relief for Hydrogen Cylinder Valves

Selected Youngdo hydrogen cylinder valves, rated 35 and 70 MPa, include a thermally activated pressure relief device that vents the cylinder in a fire.

  • Glass bulb activation at about 105–110 °C, where fitted
  • Integral to the cylinder valve
  • Certification varies by model
Activates ~105–110 °CView hydrogen cylinder valves
Gas network relief valvesPietro Fiorentini

Gas Network Relief Valves

The VS/AM 58 is a compact relief and monitor valve that protects downstream gas distribution systems against overpressure.

  • For natural gas distribution networks
  • Supplied with Pietro Fiorentini regulators and valves

At a glance

Compare the Ranges

RangeTypePressure rangeServiceConnectionsBrand
RVL / RVH / PRVHSpring-adjustable relief50 – 15,000 psiLiquids and gases on instrument linesNPT, BSPT, BSPP, tube fittingPANAM
High-pressure relief valvesProportional, field-adjustable, factory-set1,000 – 60,000 psiWater, liquid, gasUNFHiflux
Rupture discsNon-reclosing~11,500 – 60,000 psiLiquid and gasSafety head, UNFHiflux
Thermal reliefThermally activatedActivates ~105–110 °CHydrogen cylindersIntegral to cylinder valveYoungdo
VS/AM 58Relief and monitor valveBy modelNatural gas networksBy modelPietro Fiorentini

Before you order

How to Choose a Safety or Relief Valve

Work through these seven points. Not sure? Send us the fluid, set pressure, required capacity, temperature and connections, and we will match the valve.

  1. 1

    Set Pressure

    At or below the maximum allowable working pressure (MAWP) of the equipment it protects.

  2. 2

    Fluid

    Steam, gas or air usually need a safety valve; liquids a relief valve. Trapped liquid that can heat up needs a small thermal relief valve.

  3. 3

    Relieving Capacity

    The valve must pass the flow from the worst credible overpressure case, such as a blocked outlet, a failed regulator or a fire.

  4. 4

    Back Pressure

    If the outlet discharges into a header, check the back pressure. Conventional valves have limits; balanced bellows or pilot-operated designs cope with more.

  5. 5

    Connections and Size

    Match the inlet and outlet connections, and keep the inlet line short so pressure loss stays low.

  6. 6

    Materials and Seals

    Match the body, trim and seals to the fluid and temperature, for example SS 316 and FKM.

  7. 7

    Code and Certification

    Pressure vessels and boilers usually need a certified safety valve (ASME, PED/UKCA or ISO 4126). Ask for the certificate with the order.

Standards

Standards and UK Regulations

Certification varies by model, so ask for the certificates you need with your quote.

PSSR 2000

Pressure Systems Safety Regulations: the UK duty to protect pressure systems, including a written scheme of examination for protective devices.

PE(S)R 2016

Pressure Equipment (Safety) Regulations: UK conformity (UKCA) for pressure equipment and safety accessories.

PED 2014/68/EU

EU conformity (CE). Safety accessories are generally category IV.

ASME BPVC I & VIII

Safety valves for boilers (Section I) and pressure relief devices for pressure vessels (Section VIII).

API 520 / 526 / 527

Sizing and installation; flanged valve dimensions and orifice sizes; seat tightness.

ISO 4126-1

Safety valves for protection against excessive pressure.

Partner brands

The Brands Behind the Range

PANAM logo

RVL, RVH and PRVH instrumentation relief valves in SS 316.

Hiflux logo

High-pressure relief valves, rupture discs and safety heads to 60,000 psi.

Youngdo logo

Hydrogen cylinder valves with thermally activated pressure relief.

Pietro Fiorentini logo

VS/AM 58 relief and monitor valve for gas networks.

FAQ

Safety and Relief Valve FAQs

What is the difference between a safety valve and a relief valve?

A safety valve opens fully and quickly at its set pressure and is used for gases, steam and air. A relief valve opens gradually in proportion to the overpressure and is used for liquids. A safety relief valve can work either way.

What is a pressure relief valve?

Pressure relief valve is the general term for any valve that opens automatically to release pressure above a set point. Safety valves, relief valves and safety relief valves are all types of pressure relief valve.

What pressure ranges do you supply?

PANAM instrumentation relief valves cover 50 to 15,000 psi, and Hiflux high-pressure relief valves cover 1,000 to 60,000 psi. Hiflux rupture discs run from about 11,500 to 60,000 psi.

Can an instrumentation relief valve be used as a safety valve?

Not where a code requires a certified safety valve. Instrumentation relief valves protect lines and instruments; boilers and pressure vessels need a safety valve certified to the relevant code. Ask us which certificates are available for a given model.

What is a rupture disc?

A rupture disc is a thin, non-reclosing membrane that bursts at a set pressure. It is used alone, or upstream of a relief valve to protect the valve from the process fluid.

Do you supply certificates with safety and relief valves?

Certificates are available on request and vary by model. Tell us the code and certificates you need when you request a quote.

Request a Quote

Send us the fluid, set pressure, required capacity, temperature, connections and code, and we will match the right safety or relief valve from our partner brands.