Valves
Every pressure system needs a last line of defence against overpressure. Valvenok supplies pressure relief valves, high-pressure safety valves, rupture discs and thermal relief devices from specialist partner manufacturers, from 50 psi instrument lines to 60,000 psi test systems, with certificates on request.
Set pressure range across the ranges
Instrumentation relief valves, online
Relief valves, rupture discs and thermal relief
PANAM · Hiflux · Youngdo · Pietro Fiorentini
The basics
A safety valve opens fully and almost instantly (it “pops”) when pressure reaches its set point. It is used on gases, steam and air, where pressure must be released fast. A relief valve opens gradually, in proportion to the overpressure, and suits liquids. A safety relief valve can do either, depending on the service.
Our ranges
Each range has its own page with full specifications and models. Pick the one that matches your pressure and service.
PANAMCompact SS 316 relief valves for instrument, sampling and hydraulic lines, spring-adjustable from 50 to 15,000 psi in 340 configurations.
For code-required protection on boilers and pressure vessels, use a certified safety valve.
HifluxRelief valves for test rigs, hydraulic systems, hydrogen and other high-pressure service, with UNF connections.
HifluxNon-reclosing pressure relief. A rupture disc bursts at a set pressure; the safety head holds it in the line. Use it alone, or upstream of a relief valve to protect the valve from the process fluid.
YoungdoSelected Youngdo hydrogen cylinder valves, rated 35 and 70 MPa, include a thermally activated pressure relief device that vents the cylinder in a fire.
Pietro FiorentiniThe VS/AM 58 is a compact relief and monitor valve that protects downstream gas distribution systems against overpressure.
At a glance
| Range | Type | Pressure range | Service | Connections | Brand |
|---|---|---|---|---|---|
| RVL / RVH / PRVH | Spring-adjustable relief | 50 – 15,000 psi | Liquids and gases on instrument lines | NPT, BSPT, BSPP, tube fitting | PANAM |
| High-pressure relief valves | Proportional, field-adjustable, factory-set | 1,000 – 60,000 psi | Water, liquid, gas | UNF | Hiflux |
| Rupture discs | Non-reclosing | ~11,500 – 60,000 psi | Liquid and gas | Safety head, UNF | Hiflux |
| Thermal relief | Thermally activated | Activates ~105–110 °C | Hydrogen cylinders | Integral to cylinder valve | Youngdo |
| VS/AM 58 | Relief and monitor valve | By model | Natural gas networks | By model | Pietro Fiorentini |
Before you order
Work through these seven points. Not sure? Send us the fluid, set pressure, required capacity, temperature and connections, and we will match the valve.
At or below the maximum allowable working pressure (MAWP) of the equipment it protects.
Steam, gas or air usually need a safety valve; liquids a relief valve. Trapped liquid that can heat up needs a small thermal relief valve.
The valve must pass the flow from the worst credible overpressure case, such as a blocked outlet, a failed regulator or a fire.
If the outlet discharges into a header, check the back pressure. Conventional valves have limits; balanced bellows or pilot-operated designs cope with more.
Match the inlet and outlet connections, and keep the inlet line short so pressure loss stays low.
Match the body, trim and seals to the fluid and temperature, for example SS 316 and FKM.
Pressure vessels and boilers usually need a certified safety valve (ASME, PED/UKCA or ISO 4126). Ask for the certificate with the order.
Standards
Certification varies by model, so ask for the certificates you need with your quote.
Pressure Systems Safety Regulations: the UK duty to protect pressure systems, including a written scheme of examination for protective devices.
Pressure Equipment (Safety) Regulations: UK conformity (UKCA) for pressure equipment and safety accessories.
EU conformity (CE). Safety accessories are generally category IV.
Safety valves for boilers (Section I) and pressure relief devices for pressure vessels (Section VIII).
Sizing and installation; flanged valve dimensions and orifice sizes; seat tightness.
Safety valves for protection against excessive pressure.
Partner brands
FAQ
A safety valve opens fully and quickly at its set pressure and is used for gases, steam and air. A relief valve opens gradually in proportion to the overpressure and is used for liquids. A safety relief valve can work either way.
Pressure relief valve is the general term for any valve that opens automatically to release pressure above a set point. Safety valves, relief valves and safety relief valves are all types of pressure relief valve.
PANAM instrumentation relief valves cover 50 to 15,000 psi, and Hiflux high-pressure relief valves cover 1,000 to 60,000 psi. Hiflux rupture discs run from about 11,500 to 60,000 psi.
Not where a code requires a certified safety valve. Instrumentation relief valves protect lines and instruments; boilers and pressure vessels need a safety valve certified to the relevant code. Ask us which certificates are available for a given model.
A rupture disc is a thin, non-reclosing membrane that bursts at a set pressure. It is used alone, or upstream of a relief valve to protect the valve from the process fluid.
Certificates are available on request and vary by model. Tell us the code and certificates you need when you request a quote.
Send us the fluid, set pressure, required capacity, temperature, connections and code, and we will match the right safety or relief valve from our partner brands.