Panam Pneumatic Actuators in Double Acting (PD) and Spring Return (PDS) series. Double acting models available in 0°, 45°, and 90° configurations across multiple pressure ratings. Spring return models with ISO 5211 mounting and output torque up to 4,600 NM.
| Model | Series | Angle / ISO 5211 | Output Torque NM | Spring End / Max Torque NM | Air Open (L) | Air Close (L) | Details | Quote | |
|---|---|---|---|---|---|---|---|---|---|
| PD200 | PD | 0° | 3187 | 4635 | 9.07 | 9.21 | |||
| PD200 | PD | 45° | 1333 | 1939 | 9.07 | 9.21 | |||
| PD200 | PD | 90° | 2231 | 3245 | 9.07 | 9.21 | |||
| PD45 | PD | 0° | 26 | 38 | 0.12 | 0.12 | |||
| PD45 | PD | 45° | 11 | 16 | 0.12 | 0.12 | |||
| PD45 | PD | 90° | 18 | 27 | 0.12 | 0.12 | |||
| PD50 | PD | 0° | 54 | 79 | 0.16 | 0.16 | |||
| PD50 | PD | 45° | 23 | 33 | 0.16 | 0.16 | |||
| PD50 | PD | 90° | 38 | 55 | 0.16 | 0.16 | |||
| PD55 | PD | 0° | 73 | 107 | 0.34 | 0.34 | |||
| PD55 | PD | 45° | 30 | 44 | 0.34 | 0.34 | |||
| PD55 | PD | 90° | 51 | 75 | 0.34 | 0.34 | |||
| PDS-100 | PDS | F10/F10 | 120 – 885 | 70 – 260 | — | — | |||
| PDS-125 | PDS | F10/F12 | 180 – 1250 | 105 – 360 | — | — | |||
| PDS-160 | PDS | F10/F14 | 300 – 2400 | 150 – 1000 | — | — | |||
| PDS-200 | PDS | F12/F16 | 760 – 4600 | 350 – 2000 | — | — | |||
| PDS-45 | PDS | F05/F07 | 5 – 40 | 5 – 15 | — | — | |||
| PDS-50 | PDS | F05/F07 | 10 – 80 | 5 – 30 | — | — | |||
| PDS-55 | PDS | F05/F07 | 12 – 125 | 12 – 25 | — | — | |||
| PDS-70 | PDS | F07/F10 | 30 – 220 | 25 – 70 | — | — | |||
| PDS-75 | PDS | F07/F10 | 50 – 330 | 35 – 120 | — | — | |||
| PDS-85 | PDS | F07/F10 | 60 – 460 | 45 – 160 | — | — |
A scotch yoke actuator converts the straight-line movement of a pneumatic piston into a 90-degree turn using a sliding yoke. Its geometry gives the most torque at each end of the stroke and less in the middle, which suits valves that need high break-out and seating torque, such as large ball, plug and butterfly valves. The table shows this directly: torque is listed at 0°, 45° and 90°.
Two series are listed. The PD series is double acting: air pressure drives the piston both ways. Models PD45, PD50, PD55 and PD200 are shown with torque at supply pressures from 2.8 to 8 bar, and air consumption per stroke at 5.5 bar. The PDS series is spring return: air drives the actuator one way and an internal spring drives it back when air is removed, giving a fail-safe position. PDS models run from PDS-45 to PDS-200, with output torque up to 4,600 Nm, spring end torque listed separately, and ISO 5211 mounting from F05/F07 to F12/F16.
Filter by series, model and angle, then compare torque at your available air pressure with the valve's torque requirement. The series page lists ATEX and SIL capability; certification varies by model, so confirm it with Valvenok's UK team when you request a quote.