Free UK delivery on orders over £150
Valvenok
JOSCAR RegisteredBVAA member
Track Order
Quick Order
Cart
Sign In
Request a quote

Electric actuators

Susin I-Tork

QS Series Fail-safe Electric

Susin I-Tork spring return electric actuators for ball, butterfly and plug valves that must go to a safe position when the power fails. 4 models from 50 to 300 Nm; an independent spiral spring returns the valve in 1.8 seconds.

Models
QS05 · QS10 · QS20 · QS30
Torque
50 – 300 Nm
Spring return
1.8 s (2, 3, 4 s option)
Power supply
AC 110 – 440 V, 24 VDC
Enclosure
IP67 (IP68 option)
Temperature
−20 to +70 °C
How it fails safe
Power onPower lostMotorReducerBRKSpiral springSafe positionOpenMotor opens · 21–34 sSpring returns · 1.8 s
Motor drives only the reducer Spring works only on power loss
Susin I-Tork QS fail-safe electric actuator

How It’s Built

  • Magnetic brake and spiral spring. The brake holds the spring while power is on. If power is lost it releases, and the spring alone turns the valve to its safe position in 1.8 s, or 2, 3 or 4 s as an option.
  • Special reducer. The motor drives only the reducer in normal running, so it can be smaller and draw less current.
  • Switches. Two limit switches and two torque switches for open and close (SPDT 250 VAC / 10 A); two auxiliary force switches as an option.
  • On/off or modulating. S2 30 min on/off, or S4 50% modulating with a 4–20 mA signal (0–10, 0–5, 1–5 or 2–10 VDC as options).
  • Manual operation and indication. A manual handwheel and lever, stopper bolts and a mechanical position indicator on top.
  • Sealed and heated. IP67, IP68 as an option, with a 2 W space heater and six cable entries.

What’s different

A Spring That Only Works When It’s Needed

Susin I-Tork’s QS uses an independent spring structure, held by a magnetic brake, rather than a spring the motor has to drive every stroke.

Independent spring
In most spring return actuators the motor turns the reducer and the spring together. In the QS the motor turns only the reducer for normal running, and the spring works only in an emergency.
Smaller and lighter
Because the motor never has to drive the spring, the motor and reducer can be smaller, so the actuator is more compact and lighter: 22 kg for QS05 and QS10, 40 kg for QS20 and QS30.
Less current
A smaller motor draws less current than a motor that also has to drive the spring, which saves energy over the actuator’s working life.

FAQ

QS Actuator Questions

What happens when the power fails?

The magnetic brake releases and the independent spiral spring turns the valve to its safe position in 1.8 seconds (2, 3 or 4 seconds as options). In normal running the motor drives only the reducer, not the spring.

How do I choose the size?

Take the valve’s highest torque, add a safety factor, and pick the smallest QS that covers it. Motor and spring torque are the same on every model, so the valve gets the same torque on the spring stroke. Then check the ISO 5211 flange: F07 on QS05 and QS10, F10 / F12 on QS20 and QS30.

Which supply voltages can it run on?

AC 110, 220, 380 or 440 V, or 24 VDC.

Can it modulate as well as open and close?

Yes. It runs on/off (S2, 30 min) or modulating (S4, 50%) with a 4–20 mA control signal, or 0–10, 0–5, 1–5 or 2–10 VDC as options. Susin I-Tork notes that the ITQ series options are also available on the QS.

Is it suitable for hazardous areas?

No. The QS is IP67 (IP68 option) but is not available explosion proof; Susin I-Tork lists it as under development. For a hazardous area, the ITQ series has an explosion proof option.

QS or ITQ with a battery backup?

Both move the valve to a set position on power loss. The QS does it with a spring, from 50 to 300 Nm. The ITQ’s BP battery backup option does it with a rechargeable battery, on 1 phase ITQ 0160 to ITQ 0500.

Need a Valve to Fail Safe?

Compare all 4 QS models by torque, time and flange, or send us the valve torque, power supply and safe position and we’ll pick the model.