Stainless steel dielectric tube fittings for electrical isolation, and precision thread sealing gaskets for parallel and internal threads.
| Part Number | Type | Tube OD | NPT Thread | Unit | |
|---|---|---|---|---|---|
| PMC-06-4N-SS-DIE | Male Connector | 3/8(in) | 1/4" | Imperial | |
| PMC-08-4N-SS-DIE | Male Connector | 1/2(in) | 1/4" | Imperial | |
| PMC-M12-4N-SS-DIE | Male Connector | 12(mm) | 1/4" | Metric | |
| PU-04-SS-DIE | Union | 1/4(in) | — | Imperial | |
| PU-06-SS-DIE | Union | 3/8(in) | — | Imperial | |
| PU-08-SS-DIE | Union | 1/2(in) | — | Imperial | |
| PU-M06-SS-DIE | Union | 6(mm) | — | Metric | |
| PU-M08-SS-DIE | Union | 8(mm) | — | Metric | |
| PU-M10-SS-DIE | Union | 10(mm) | — | Metric | |
| PU-M12-SS-DIE | Union | 12(mm) | — | Metric |
Where two parts of a tubing system sit at different electrical potentials, current can flow through the metal and cause galvanic corrosion or interfere with cathodic protection. A dielectric fitting breaks that path. These SS316 unions and male connectors include a polyamideimide insulator between the two halves, so fluid passes through while the electrical path is interrupted. The fittings carry a stated pressure rating of 34.47 MPa (5000 PSI).
Dielectric unions are listed for 1/4", 3/8" and 1/2" tube OD and 6 mm to 12 mm metric tube. Dielectric male connectors combine a tube end with a 1/4" NPT male thread. Typical uses include cathodic protection systems, offshore installations and chemical plant.
The same page lists thread sealing gaskets for parallel and internal threads, which do not seal on the thread flanks. The PRS, PRP and PRG types suit ISO parallel (G), RP and internal ISO threads, plus their metric parallel and internal equivalents. Sizes run from 1/8" to 2" and M8 x 1.0 to M48 x 2.0, with SS316, carbon steel and copper options shown in the specifications.